2 Installation and commissioning
2.4.1. Pre-installation procedure
3HAC027151-001 Revision: B
48
©
Co
py
rig
h
t 200
6-
200
8 ABB. All righ
ts reser
v
ed.
* When using base spacers (option 571-1).
Requirements, foundation
The table below shows the requirements for the foundation where the weight of the installed
robot is included:
Storage conditions, robot
The table below shows the allowed storage conditions for the robot:
Operating conditions, robot
The table below shows the allowed operating conditions for the robot:
Protection classes, robot
The table below shows the protection class of the robot:
Torque xy
± 19.0 kNm
± 18.0 kNm*
± 32.5 kNm
± 37.2 kNm*
Torque z
± 4.4 kNm
± 10.4 kNm
Force
Endurance load (operation)
Max. load (emergency stop)
Requirement
Value
Note
Min. levelity
0.5 mm
Max. tilt
15°
The limit for the maximum load on the robot
is reduced if the robot is tilted.
Contact ABB for further information about
acceptable loads.
Min. resonance frequency
22 Hz
Parameter
Value
Min. ambient temperature
-25° C
Max. ambient temperature
+55° C
Max. ambient temperature (less than 24 hrs)
+70° C
Max. ambient humidity
Max. 95% at constant temperature
Parameter
Value
Min. ambient temperature
+5° C
Max. ambient temperature
+50° C
Max. ambient humidity
Max. 95% at constant temperature
Equipment
Protection class
Robot
IP 54
Upper arm, including wrist
IP 67
Continued