3 Maintenance
3.3.2. Inspection, oil level gearbox axis 2
3HAC026876-001 Revision: C
118
© Copyri
ght
200
6-2008 ABB.
All rights reserved.
2.
DANGER!
Turn off all electric power, hydraulic and
pneumatic pressure supplies to the robot!
For Foundry Prime robots: Do not turn off the air
pressure to motors and SMB.
3. Open the oil plug, filling.
Shown in the figure
4. Measure the oil level at the oil plug, filling.
Required oil level: max. 5 mm below the oil plug
hole.
Shown in the figure
5. Add oil if required.
Filling of oil is detailed further in
section
6. Refit the oil plug, filling.
Tightening torque: 24 Nm.
Action
Note
Continued