3 Maintenance
3.3.4. Inspection, oil level gearbox axis 4
3HAC026876-001 Revision: C
122
© Copyri
ght
200
6-2008 ABB.
All rights reserved.
3.
DANGER!
Turn off all electric power, hydraulic and
pneumatic pressure supplies to the robot!
For Foundry Prime robots: Do not turn off the
air pressure to motors and SMB.
4. Open the oil plug, filling.
.
5. Required oil level: max 10 mm below the oil
plug hole.
6. Add oil if required.
Further information about how to fill the
oil may be found in section
.
7. Refit the oil plug.
Tightening torque: 24 Nm.
Action
Note
Continued