4 Repair
4.3.3. Replacement of cable harness, Cleanroom
213
3HAC026876-001 Revision: C
© Copyri
ght
200
6-2008 ABB.
All rights reserved.
Removal cable harness - upper end
The procedure below details how to remove the upper end of the cable harness, Cleanroom.
Action
Note
1. Remove the cover at the back of the upper arm tube
by removing its attachment screws.
cable harness, Cleanroom on
page 207
2. Remove the cable harness from motor axis 5 and
motor axis 6, as well as from the wrist.
This procedure is the same as for the standard
cable harness of the robot.
Detailed in section
cable harness - upper arm on
page 195
3. Remove the cable clamp on the armhouse by
removing its attachment screws.
cable harness, Cleanroom on
page 207
4. Disconnect all connectors at motor axis 3 and motor
axis 4.
cable harness, Cleanroom on
page 207
5. Carefully pull out the cable harness from the upper
arm tube.
6. Disconnect all connectors at the connection plate
axis 3.
xx0800000055
Parts:
•
A: Connectors (at
connection plate axis 3)
7. Open the the gripping clamp on the bracket for cable
clamp.
xx0800000056
Parts:
•
A: Gripping clamp
•
B: Cable harness
•
C: Bracket for cable clamp
8. Remove the cable harness from the robot.
Continued
Continues on next page