4 Repair
4.3.6. Replacement of complete arm system
241
3HAC026876-001 Revision: C
© Copyri
ght
200
6-2008 ABB.
All rights reserved.
10. Refit the calibration plate at the bottom of the
frame.
xx0700000380
Parts:
•
A: Calibration plate
11. Refit the motor axis 1.
Detailed in section
.
12. Refit the cabling in the base.
harness, Cleanroom on page 207
.
13. Perform a leak-down test of the gearbox axis
1.
Detailed in section
.
14. Refill the gearbox axis 1 with lubricating oil.
Detailed in section
.
15. Recalibrate the robot.
Calibration is detailed in a separate
calibration manual, enclosed with the
calibration tools.
General calibration information is
included in section
Calibration informa-
tion
.
16.
DANGER!
Make sure all safety requirements are met
when performing the first test run. These are
further detailed in section
test run may cause injury or damage! on
page 33
.
Action
Note
Continued