4 Repair
4.3.1. Replacement of cable harness, axes 1-6
3HAC026876-001 Revision: F
208
© Copyri
ght
200
7-2010 ABB.
All rights reserved.
9. Remove the cable gland by removing the four
attachment screws from inside the SMB
recess.
xx0700000109
•
A: Cable gland
•
B: Attachment screws, inside
SMB recess
10. Remove the velcro strap and cable gland
11. Remove the cable gland securing the cables to
the arm house.
xx0100000143
12. Remove the velcro strap from the harness at
the guide plate ax 2 at the lower arm.
Shown in the figure
.
13. Remove the cable harness from the cable
guide plate ax 2.
14. Disconnect all connectors at motors 3 and 4.
15. Gently pull the cable harness out.
Action
Note
Continued
Continues on next page