4 Repair
4.4.4. Replacement of upper arm
3HAC026876-001 Revision: F
278
© Copyri
ght
200
7-2010 ABB.
All rights reserved.
21. Recalibrate the robot.
Calibration is detailed in a separate
calibration manual enclosed with the
calibration tools.
General calibration information is
included in the section
Calibration infor-
mation
.
22.
DANGER!
Make sure all safety requirements are met
when performing the first test run. These are
further detailed in the section
test run may cause injury or damage! on page
41
Action
Note
Continued