3 Maintenance
3.4.8. Replacement of SMB battery
183
3HAC026876-001 Revision: F
© Copyri
ght
200
7-2010 ABB.
All rights reserved.
3.4.8. Replacement of SMB battery
NOTE!
The SMB lithium battery lifetime can be extended significantly during a production break.
Activate sleep mode in IRC5 by a service routine that is described in Operating manual –
IRC5 with FlexPendant, chapter Battery shutdown service routine.
Location of SMB battery
The SMB battery (SMB = serial measurement board) is located on the left hand side of the
frame as shown in the figure below.
xx0600003444
Required equipment
A
Cover, battery box
B
Battery pack
C
Cable, battery
D
Battery holder
Equipment, etc.
Spare part no.
Note
Battery pack
3HAC16831-1
Battery includes protection circuits. Replace it
only with a given spare part number or an ABB
approved equivalent.
Standard toolkit
-
The content is defined in the section
.
Circuit Diagram
-
3HAC025744-001
See the chapter
Circuit diagram
.
Continues on next page