4 Repair
4.3.1. Replacement of cable harness, axes 1-6
205
3HAC026876-001 Revision: F
© Copyri
ght
200
7-2010 ABB.
All rights reserved.
Cable brackets of the upper arm
xx0500002293
Removal, cable harness - upper arm
The procedure below details how to remove the cable harness from the upper arm of the robot.
A
Cable bracket, wrist unit
B
Cable bracket, upper arm tube
C
Cable attachment, rear
Action
Note
1. In order to facilitate refitting of cable harness,
run the robot to the specified position:
•
Axis 1: 0 °
•
Axis 2: 0 °
•
Axis 3: 0 °
•
Axis 4: 0 °
•
Axis 5: +90 °
•
Axis 6: no significance
Axes 2 and 3 may be tilted slightly to
improve access.
2.
DANGER!
Turn off all electric power, hydraulic and
pneumatic pressure supplies to the robot!
For Foundry Prime robots:
Do not turn off the air pressure to motors and
SMB.
3. Remove the cover, wrist unit and the cover,
upper arm tube.
xx0200000214
A. Cover, wrist unit
B. Cover, upper arm tube
Continued