4 Repair
4.3.1. Replacement of cable harness, axes 1-6
209
3HAC026876-001 Revision: F
© Copyri
ght
200
7-2010 ABB.
All rights reserved.
Refitting, cable harness - lower arm, frame and base
The procedure below details how to refit the lower end of the cable harness to the robot.
How to refit the upper end is detailed in section
Refitting, cable harness - upper arm on page
.
Action
Note
1. Pull the cable and connectors down through
the cable guide in the center of the frame.
Shown in the figure
Make sure the cables are not twisted
with each other or with eventual
customer harnesses!
Make a note of the correct positions of
the connectors!
2. Reconnect connectors R1.MP and R1.SMB at
the base.
Shown in the figure
Make a note of the correct positions of
the connectors!
3. Reconnect the earth cable.
4. Refit the rear cover plate to the robot with its
attachment screws.
Shown in the figure
5. Reconnect all connectors at motors 1 and 2.
6. Secure the cable gland with four attachment
screws from inside the SMB recess.
Refit the velcro strap. (Shown in the figure
Location of cable harness on page 203
xx0700000109
•
A: Cable gland
•
B: Attachment screws, inside
SMB recess
Continued
Continues on next page