4 Repair
4.3.1. Replacement of cable harness, axes 1-6
213
3HAC020993-001 Revision: G
©
Co
py
rig
h
t 200
4-
200
8 ABB. All righ
ts reser
v
ed.
14. Refit the cable gland securing the cables to the
arm house.
Make sure not to twist the harness!
xx0100000143
15. Reconnect all connectors at motor 3 and motor
4.
16. Secure the cable harness to the upper arm
house by refitting the
velcro strap
to the cable
bracket at the upper arm house.
17. Gently insert the cable harness from the rear
into the upper arm.
18. Connect the two connectors inside the upper
arm tube, R3.FB5 and R3.MP5 and secure the
cable bracket
with the two attachment screws
to the tube.
Shown in the figure
.
19. Place the cabling to motor, axis 6, correctly on
the upper arm and gently pull the connectors
through the hole on top of wrist unit to motor,
axis 6.
xx0200000185
In case of excess cable length: put a
loop of cable in this area with cable
straps (A). The cables are longer in
order to fit different upper arm lengths.
Action
Note
Continued
Continues on next page