2 Installation and commissioning
2.4.5. Installation of position switches (option)
93
3HAC020993-001 Revision: G
©
Co
py
rig
h
t 200
4-
200
8 ABB. All righ
ts reser
v
ed.
Axis 1
The illustration below shows the position switch for axis 1. There is no extra cabling installed
on the robot, as for axes 2 and 3. Instead the switch is connected directly to the connector in
the base, R1.SW1.
xx0100000158
Specifications
Maximum voltage/current for the position switches:
Connections
The position switches are connected to different points on the robot system:
•
XT8, screw terminal in the controller cabinet when position switch cables are used.
•
R1.SW1 at the robot base. Customer connection kit is recommended, art. no. is
specified in
•
R1.SW2/3 at the robot base. Customer connection kit is recommended, art. no. is
specified in
Further information about the cables and connection points, see section
.
A
Position switch, axis 1
B
Cam
C
Set screw, cam (cam stop)
D
Protection sheet
E
Rail
F
Rail attachment
Parameter
Value
Voltage
Max. 50 VDC
Current
Max. 1 A
Continued
Continues on next page