5.5. Updating revolution counters
General
This section details how to perform a rough calibration of each robot axis, i.e. updating the
revolution counter value for each axis, using the pendant.
Step 1 - Manually running the robot to the calibration position
This procedure details the first step when updating the revolution counter; manually running
the robot to the calibration position.
Step 2 - Storing the revolution counter setting with the TPU
This section details the second step when updating the revolution counter; storing the
revolution counter setting with the TPU (RobotWare 4.0).
Action
Note
1. Select axis-by-axis motion mode.
2. Jog the robot to place the
calibration marks
within the tolerance zone.
correct axis position on page 368
.
3. When all axes are positioned, store the
revolution counter settings.
Detailed in section:
Step 2 - Storing the revolution counter
setting with the TPU on page 370
(RobotWare 4.0).
Step 2 - Storing the revolution counter
setting with the FlexPendant on page 371
(RobotWare 5.0).
Action
Note
1. Press the button "Miscellaneous" then ENTER to select the service
window.
xx0100000194
2. Select
Calibration
from the
View
menu.
The Calibration window appears.
If there is more than one unit connected to the robot, they will be listed
in the window.
xx0100000201
Continues on next page