4 Repair
4.6.5. Replacement of motor, axis 5
331
3HAC020993-001 Revision: G
©
Co
py
rig
h
t 200
4-
200
8 ABB. All righ
ts reser
v
ed.
Replacement of the motor axis 5 (Foundry Prime)
Robots working with Foundry Prime and that have the special tightness for this application
require special repair routines to maintain the tightness level.
The repair must be done according to the previous repair procedures with the following
additions.
Action
Note/Illustration
1.
DANGER!
Turn off all electric power, hydraulic and
pneumatic pressure supplies to the robot!
For Foundry Prime robots: Do not turn off the
air pressure to motors and SMB.
2. Perform step 2 - 4 in
3. Remove the cover for connector access on
top of the motor by unscrewing its four
attachment screws.
xx0600002904
•
A: attachment screw
•
B: air hose
•
C: top cover
•
D: motor unit
4.
note
NOTE!
Keep the old
top cover
with air nipple
mounted.
5. Disconnect all connectors beneath the motor
cover and remove the separate cable of the
axis 5 motor.
Continued
Continues on next page