Inspecting, mechanical stops
Use this procedure to inspect the additional mechanical stops.
Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot working area.
1
Shown in figure
Make sure no additional stops are damaged.
2
Make sure the stops are properly attached.
3
Correct tightening torque, additional mechanical
stops:
•
Axis 1 = 120 Nm.
•
Axes 2 and 3 = 115 Nm
Article number is specified in
Required equipment on page 164
If any damage is detected, the mechanical stops must
be replaced.
Correct attachment screws:
•
Axis 1: M16 x 35, quality 12.9.
•
Axis 2: M16 x 50
•
Axis 3: M16 x 60
4
Product manual - IRB 6650S
165
3HAC020993-001 Revision: Z
© Copyright 2004-2018 ABB. All rights reserved.
3 Maintenance
3.3.12 Inspecting the additional mechanical stops
Continued