Note
Action
Locking liquid is specified in
.
xx0300000560
Secure the
cable gland
with four
attachment
screws
from inside the SMB recess.
Secure the correct
attachment plate
to the
cable gland with its two attachment screws,
using locking liquid.
Refit the
velcro strap
. Shown in the figure
Location of cable harness on page 219
.
Note
Different robot versions are fitted with different
versions of the attachment plate. Make sure
the correct one is used to avoid cable failure.
6
A Cable gland
B Attachment screws, cable gland
C Attachment plate
D Velcro strap
Continues on next page
226
Product manual - IRB 6650S
3HAC020993-001 Revision: Z
© Copyright 2004-2018 ABB. All rights reserved.