Note
Art. no.
Equipment, etc.
For guiding the motor.
3HAC15520-2
Guide pins M8 x 150
Used to rotate the motor pinion
when mating it to the gear when
brakes are released with 24 VDC
power supply.
3HAC17105-1
Rotation tool
24 VDC, max. 1,5 A
-
Power supply
For releasing the brakes.
Content is defined in section
.
-
Standard toolkit
Complete kit that also includes
operating manual.
3HAC15716-1
Calibration Pendulum toolkit
Required if Calibration Pendulum
is the valid calibration method for
the robot.
Delivered as a set of calibration
tools.
3HAC055412-001
Calibration tool box, Axis Calibra-
tion
Required if Axis Calibration is the
valid calibration method for the
robot.
These procedures include refer-
ences to the tools required.
Other tools and procedures may
be required. See references to
these procedures in the step-by-
step instructions below.
See chapter
.
Circuit diagram
Deciding calibration routine
Decide which calibration routine to be used, based on the information in the table.
Depending on which routine is chosen, action might be required prior to beginning
the repair work of the robot, see the table.
Note
Action
Decide which calibration routine to use for
calibrating the robot.
•
Reference calibration. External cable
packages (DressPack) and tools can
stay fitted on the robot.
•
Fine calibration. All external cable
packages (DressPack) and tools
must be removed from the robot.
1
Follow the instructions given in the refer-
ence calibration routine on the FlexPendant
to create reference values.
If the robot is to be calibrated with refer-
ence calibration:
Find previous reference values for the axis
or create new reference values. These val-
ues are to be used after the repair proced-
ure is completed, for calibration of the ro-
bot.
Creating new values requires possibility to
move the robot.
Read more about reference calibration for
Axis Calibration in
.
If no previous reference values exist, and
no new reference values can be created,
then reference calibration is not possible.
Read more about reference calibration for
Pendulum Calibration in
Operating manu-
al - Calibration Pendulum
.
Continues on next page
Product manual - IRB 6650S
339
3HAC020993-001 Revision: Z
© Copyright 2004-2018 ABB. All rights reserved.
4 Repair
4.6.4 Replacement of motor, axis 4
Continued
Summary of Contents for IRB 6650S Series
Page 1: ...ROBOTICS Product manual IRB 6650S ...
Page 20: ...This page is intentionally left blank ...
Page 50: ...This page is intentionally left blank ...
Page 210: ...This page is intentionally left blank ...
Page 416: ...This page is intentionally left blank ...
Page 422: ...This page is intentionally left blank ...
Page 426: ...This page is intentionally left blank ...
Page 449: ......