5.1.3 When to calibrate
When to calibrate
The system must be calibrated if any of the following situations occur.
The resolver values are changed
If resolver values are changed, the robot must be recalibrated using the calibration
methods supplied by ABB. Calibrate the robot carefully with standard calibration,
according to information in this manual.
If the robot has
absolute accuracy
calibration, it is also recommended, but not
always necessary to calibrate for new absolute accuracy.
The resolver values will change when parts affecting the calibration position are
replaced on the robot, for example motors or parts of the transmission.
The revolution counter memory is lost
If the revolution counter memory is lost, the counters must be updated. See
Updating revolution counters on page 396
. This will occur when:
•
The battery is discharged
•
A resolver error occurs
•
The signal between a resolver and measurement board is interrupted
•
A robot axis is moved with the control system disconnected
The revolution counters must also be updated after the robot and controller are
connected at the first installation.
The robot is rebuilt
If the robot is rebuilt, for example, after a crash or when the reach ability of a robot
is changed, it needs to be recalibrated for new resolver values.
If the robot has
absolute accuracy
calibration, it needs to be calibrated for new
absolute accuracy.
Product manual - IRB 6650S
393
3HAC020993-001 Revision: Z
© Copyright 2004-2018 ABB. All rights reserved.
5 Calibration
5.1.3 When to calibrate
Summary of Contents for IRB 6650S Series
Page 1: ...ROBOTICS Product manual IRB 6650S ...
Page 20: ...This page is intentionally left blank ...
Page 50: ...This page is intentionally left blank ...
Page 210: ...This page is intentionally left blank ...
Page 416: ...This page is intentionally left blank ...
Page 422: ...This page is intentionally left blank ...
Page 426: ...This page is intentionally left blank ...
Page 449: ......