Note
Action
All mechanical units connected to the system are
shown with their calibration status.
2
Tap the mechanical unit in question.
xx1500000943
The FlexPendant will give all inform-
ation needed to proceed with Axis
Calibration.
Calibration method used at factory for each axis
is shown, as well as calibration method used for
the robot during last field calibration.
3
Tap
Run Calibration Method
. The software will
automatically call for the procedure for the valid
calibration method.
xx1500000944
A brief overview of the sequence
that will be run on the FlexPendant
is given in
tion procedure on the FlexPendant
on page 406
Follow the instructions given on the FlexPendant.
4
Restarting an interrupted calibration procedure
If the Axis Calibration procedure is interrupted before the calibration is finished,
the RobotWare program needs to be started again. Use this procedure to take
required action.
Action
Situation
Press and hold the three-position enabling
device and press
Play
.
The three-position enabling device on the
FlexPendant has been released during robot
movement.
Continues on next page
408
Product manual - IRB 6650S
3HAC020993-001 Revision: Z
© Copyright 2004-2018 ABB. All rights reserved.
5 Calibration
5.4.4 Axis Calibration - Running the calibration procedure
Continued
Summary of Contents for IRB 6650S Series
Page 1: ...ROBOTICS Product manual IRB 6650S ...
Page 20: ...This page is intentionally left blank ...
Page 50: ...This page is intentionally left blank ...
Page 210: ...This page is intentionally left blank ...
Page 416: ...This page is intentionally left blank ...
Page 422: ...This page is intentionally left blank ...
Page 426: ...This page is intentionally left blank ...
Page 449: ......