4 Repair
4.6.3. Replacement of motor, axis 4
3HAC028197-001 Revision: A
234
©
Co
py
rig
h
t 200
7-
200
8 ABB. All righ
ts reser
v
ed.
12. Refit the cover on top of the motor with its
four attachment screws.
Make sure the cover is tightly sealed!
13. Refit the
cable gland cover
at the cable exit
with its two attachment screws.
Shown in the figure
.
14. Perform a leak-down test if gearbox has
been drained.
Detailed in section
.
15. Refill the gearbox with oil if drained.
16. Recalibrate the robot!
Calibration is detailed in a separate
calibration manual, enclosed with the
calibration tools.
General calibration information is
included in section
Calibration informa-
tion
.
17.
DANGER!
Make sure all safety requirements are met
when performing the first test run. These are
further detailed in section
test run may cause injury or damage! on
page 33
.
Action
Note