2 Installation and commissioning
2.3.10. Installation of cooling fan for motors, axis 1 or 2 (option)
3HAC028197-001 Revision: A
74
©
Co
py
rig
h
t 200
7-
200
8 ABB. All righ
ts reser
v
ed.
Plate for customer connections, at base
xx0500002301
Installation, fan
The procedure below details how to install the cooling fan on motors, axes 1 or 2 .
Locking liquid
-
Loctite 243. Used for the three tightening
screws.
Standard toolkit
-
The content is defined in section
Circuit diagram
3HAC025744-001
See chapter
Circuit diagram
.
Other tools and procedures
may be required. See
references to these
procedures in the step-by-
step instructions below.
These procedures include references to
the tools required.
Equipment
Art. no.
Note
A
Plate for customer connections
B
Attachment screws, 3 pcs, M6x16 quality 8.8-A2F
Action
Note
1.
DANGER!
Turn off all electric power, hydraulic and pneumatic pressure
supplies to the robot!
Continued
Continues on next page