4 Repair
4.6.1. Replacement of motor, axis 1
3HAC028197-001 Revision: A
224
©
Co
py
rig
h
t 200
7-
200
8 ABB. All righ
ts reser
v
ed.
3. Remove the
cable gland cover
at the cable exit
by unscrewing its attachment screw which is
found after removing the motor cover.
Shown in the figure
Make sure the gasket is not damaged!
xx0600002694
•
A: Screw holding the cable
gland
4. Disconnect all connectors beneath the motor
cover.
5. In order to release the brake, connect the 24
VDC power supply.
Connect to connector R2.MP1
•
+ : pin 2
•
- : pin 5
6. Remove the motor by unscrewing its four
attachment screws
and plain washers.
Shown in the figure
7. If required, press the motor out of position by
fitting two screws in the holes on the motor for
pressing out the motor.
Always use the removal screws in
pairs!
8.
CAUTION!
The motor weighs 29 kg! All lifting equipment
used must be sized accordingly!
9. Lift the motor to get the pinion away from the
gear and disconnect the brake release voltage.
10. Remove the motor by gently lifting it straight up.
11. Check the pinion. If there is any damage, the
pinion must be replaced.
NOTE!
If the gearbox is replaced, the motor pinion
must also be replaced!
Action
Note
Continued
Continues on next page
Summary of Contents for IRB 6660 - 130/3.1
Page 1: ...Product manual Articulated robot IRB 6660 130 3 1 IRB 6660 205 1 9 M2004 ...
Page 2: ......
Page 332: ... 0 1 23 3 4 5 5 6 2 70 2 888 2 9 6 0 9 9 2 A 8B C D 9 8 B ...
Page 333: ... 2 3 4 5 5 6 2 70 2 888 2 9 6 0 9 9 1 EF 2 888 2 9 6 9 9 8 B ...
Page 336: ... 98 2 888 7 066 0 10I 4 5 5 06 6 2 70 2 888 2 9 6 0 9 9 G E 7 F E 7 F 9 8 B ...
Page 347: ......