Inspection, cable harness
The procedure below details how to inspect the cable harness axes 1-6.
Note
Action
DANGER
Turn off all electric power, hydraulic and pneumat-
ic pressure supplies to the robot!
1
Make an overall visual inspection of the cable
harness in order to detect wear and damage.
2
Shown in the figure
Check the connectors at the base.
3
Shown in the figure
Check the metal clamps at the rear of the upper
arm and in the upper arm tube.
4
Check that the velcro straps and the mounting
plate are properly attached to the frame.
5
Check the cabling leading into the lower arm.
Make sure it is attached by the straps and not
damaged.
6
Detailed in sections
of cable harness, lower end (axes
1-3) on page 181
and
of cable harness, upper end on
page 196
.
Replace the cable harness if wear, cracks or
damage is detected.
7
Product manual - IRB 6660
133
3HAC028197-001 Revision: S
© Copyright 2007-2018 ABB. All rights reserved.
3 Maintenance
3.3.7 Inspection, cable harness
Continued