Removal, cable harness - lower end (axes 1-3)
The procedure below details how to remove the cable harness, lower end (axes
1-3).
Note
Action
This is done in order to facilitate updat-
ing of the revolution counter.
Move the robot to the calibration position.
1
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot working
area.
2
Shown in
lower end (axes 1-3) on page 181
.
Remove the
rear cover plate
on the robot by
removing its attachment screws.
3
Shown in
lower end (axes 1-3) on page 181
.
Disconnect the
earth cable
.
4
Shown in
lower end (axes 1-3) on page 181
.
Disconnect connectors
R1.MP
and
R1.SMB
.
5
xx0600002698
•
A: Cable guide ax 2
Remove the cable guide axis 2.
6
Shown in
lower end (axes 1-3) on page 181
Unscrew the screws in the
metal clamps
holding
the cable harness in the frame and lower arm.
7
Remove the motor cover, axis 1, 2, 3 by remov-
ing its attachment screws, in order to reach the
connectors.
8
Disconnect all connectors at motor 1, 2 and 3.
9
Continues on next page
Product manual - IRB 6660
183
3HAC028197-001 Revision: S
© Copyright 2007-2018 ABB. All rights reserved.
4 Repair
4.3.1 Replacement of cable harness, lower end (axes 1-3)
Continued
Summary of Contents for IRB 6660
Page 1: ...ROBOTICS Product manual IRB 6660 ...
Page 8: ...This page is intentionally left blank ...
Page 18: ...This page is intentionally left blank ...
Page 48: ...This page is intentionally left blank ...
Page 108: ...This page is intentionally left blank ...
Page 172: ...This page is intentionally left blank ...
Page 366: ...This page is intentionally left blank ...
Page 386: ...This page is intentionally left blank ...
Page 388: ...This page is intentionally left blank ...
Page 394: ......
Page 395: ......