Note
Action
xx1000001379
Lift the parallel arm, lower it and put it in mounting
position with the lower arm.
13
Art. no. is specified in
.
Carefully press the parallel arm onto the lower arm
using the
pressing tool, lower arm
.
14
Fit the big and small VK cover.
15
Detailed in section
complete lower arm on page 244
Refit the complete lower arm.
16
Pendulum Calibration is described
in
Operating manual - Calibration
Pendulum
, enclosed with the cal-
ibration tools.
Recalibrate the robot.
17
Axis Calibration is described in
Calibrating with Axis Calibration
method on page 352
.
General calibration information is
included in section
.
DANGER
Make sure all safety requirements are met when
performing the first test run. These are further de-
tailed in the section
First test run may cause injury
18
258
Product manual - IRB 6660
3HAC028197-001 Revision: S
© Copyright 2007-2018 ABB. All rights reserved.