Decommissioning at decommissioning company, balancing device
The instruction below details how to decommission the balancing device. Contact
ABB Robotics for further consultation.
Note
Action
DANGER
There is stored energy built up by high
tensioned compression springs inside the
balancing device! When a coil is cut the
released tension creates a spatter of
sparks and flames.
The working area must be free of flam-
mable materials. Position the balancing
device so that the spatter will be directed
away from personnel.
1
Clamp the device at the working location.
Place the device at ground level so that
the hole and spring coils are cut from a
more safe distance.
2
DANGER
The hole must be cut as specified in the
figure. Pieces can be ejected from the cyl-
inder at high speed if the hole is cut larger
than specified!
3
Use a cutting torch with a long shaft.
Cut a hole in the housing as shown in the
figure.
4
The measurements shown below are maxim-
um values!
xx0700000155
Continues on next page
Product manual - IRB 6660
371
3HAC028197-001 Revision: S
© Copyright 2007-2018 ABB. All rights reserved.
6 Decommissioning
6.4 Decommissioning of balancing device
Continued
Summary of Contents for IRB 6660
Page 1: ...ROBOTICS Product manual IRB 6660 ...
Page 8: ...This page is intentionally left blank ...
Page 18: ...This page is intentionally left blank ...
Page 48: ...This page is intentionally left blank ...
Page 108: ...This page is intentionally left blank ...
Page 172: ...This page is intentionally left blank ...
Page 366: ...This page is intentionally left blank ...
Page 386: ...This page is intentionally left blank ...
Page 388: ...This page is intentionally left blank ...
Page 394: ......
Page 395: ......