2.3.6 Securing the base plate
Base plate, dimensions
A
A
B
B
C
D
G
H
E
F
2x R525
598,31
560,85
487,01
243,5
0
73,84
111,30
1020
857,3
73,84
132,64
317,3
502,04
560,85
634,68
0
2x 50x45º
231,5
2x 450
950
(Ø 800)
12x M24
Ø1 A
455
C
A
4x48
13
(2)
1,6
3x45º
0.3
Ø 45P7
A-A
Ø1.5
(4x)
6,3
(48)
(2)
1,6
3x45º
B-B
(2)
13
3x R1
3x4
3x 90º
C-C
45
K
7
+0,5
0
47
0,25 c
(2x R22,5)
1,6
D
(2)
c
52,5º
Common Zone
E, F, G, H
xx1000001053
Common tolerance zone (accuracy all over the base plate from one contact
surface to the other)
E, F, G, H
Continues on next page
76
Product manual - IRB 6660
3HAC028197-001 Revision: S
© Copyright 2007-2018 ABB. All rights reserved.
2 Installation and commissioning
2.3.6 Securing the base plate