Note
Action
xx1200000952
Inspect the oil level at the vent hole (level
plug).
6
Required oil level is: 0-15 mm below the oil
plug hole.
More information is found in
oil level in axis-2 gearbox on page 124
.
Remove the oil dispenser.
7
Refit the protective cap on the nipple.
Tightening torque: 24 Nm
Refit the level plug.
8
DANGER
Make sure all safety requirements are met
when performing the first test run. These
are further detailed in the section
run may cause injury or damage on
page 26
.
9
Product manual - IRB 6700
169
3HAC044266-001 Revision: N
© Copyright 2013 - 2018 ABB. All rights reserved.
3 Maintenance
3.4.3 Changing oil, axis-2 gearbox
Continued