Note
Action
xx1200000955
IRB 6700 - 235/2.65, IRB 6700 - 205/2.80,
IRB 6700 - 175/3.05, IRB 6700 - 150/3.20,
IRB 6700 - 200/2.60, IRB 6700 - 155/2.85
Inspect the oil level at the vent hole (level
plug).
7
xx1500001645
IRB 6700 - 300/2.70, IRB 6700 - 245/3.00
Required oil level is: 0 - 20 mm below the
oil plug hole.
More information is found in
oil level in axis-3 gearbox on page 127
.
Remove the oil dispenser.
8
Refit the protective cap on the nipple.
Tightening torque: 24 Nm
Refit the level plug.
9
DANGER
Make sure all safety requirements are met
when performing the first test run. These
are further detailed in the section
run may cause injury or damage on
page 26
.
10
Product manual - IRB 6700
175
3HAC044266-001 Revision: N
© Copyright 2013 - 2018 ABB. All rights reserved.
3 Maintenance
3.4.4 Changing oil, axis-3 gearbox
Continued