Note
Action
Choose figure depending on which plate
is installed on the robot.
xx1500001029
Cut the cable ties that hold the cable har-
ness to the plate.
Note
Keep the heat protection plate until refitting.
Tip
If removing the plate only for replacing the
motor, the cabling does not need to be
loosened from the plate.
6
xx1300000489
Disconnecting the axis-6 motor cables
Note
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
Continues on next page
Product manual - IRB 6700
235
3HAC044266-001 Revision: N
© Copyright 2013 - 2018 ABB. All rights reserved.
4 Repair
4.4.1 Removing the cable harness
Continued