Note
Action
xx1300000729
Connect the battery cable to the SMB unit.
Make sure the lock snaps into place during refit-
ting.
3
xx1300000728
Connect all connectors to the SMB board:
•
R1.SMB1-3, R1.SMB4-6 and R2.SMB
4
xx1300000730
Push in the SMB unit carefully into position and
fit the bracket that secures the SMB unit.
5
X9
X8
X10
xx1700000978
If disconnected, reconnect the connectors X8,
X9 and X10 to the brake release board.
Be careful not to damage the sockets or pins.
Make sure the connector and its locking arms
are snapped down properly.
6
Continues on next page
Product manual - IRB 6700
263
3HAC044266-001 Revision: N
© Copyright 2013 - 2018 ABB. All rights reserved.
4 Repair
4.4.2 Refitting the cable harness
Continued
Summary of Contents for IRB 6700 Series
Page 1: ...ROBOTICS Product manual IRB 6700 ...
Page 46: ...This page is intentionally left blank ...
Page 110: ...This page is intentionally left blank ...
Page 786: ...This page is intentionally left blank ...
Page 812: ...This page is intentionally left blank ...
Page 836: ...This page is intentionally left blank ...
Page 838: ...This page is intentionally left blank ...
Page 845: ......