Removing the SMB unit
Use these procedures to disconnect and remove the SMB unit.
Preparations before disconnecting the SMB unit
Note
Action
DANGER
Make sure that all supplies for electrical power, hy-
draulic pressure, and air pressure are turned off.
1
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the unit
please read the safety information in the section
unit is sensitive to ESD on page 31
2
xx1300000829
Open the small cover on the SMB cover, disconnect
the battery cable and remove the battery.
3
xx1300000669
Remove the SMB cover.
CAUTION
Clean cover from metal residues before opening.
Metal residues can cause shortage on the boards
which can result in hazardous failures.
4
Disconnecting and removing the SMB unit
Note
Action
DANGER
Make sure that all supplies for electrical power, hy-
draulic pressure, and air pressure are turned off.
1
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the unit
please read the safety information in the section
unit is sensitive to ESD on page 31
2
Continues on next page
286
Product manual - IRB 6700
3HAC044266-001 Revision: N
© Copyright 2013 - 2018 ABB. All rights reserved.
4 Repair
4.4.3 Replacing the SMB
Continued
Summary of Contents for IRB 6700 Series
Page 1: ...ROBOTICS Product manual IRB 6700 ...
Page 46: ...This page is intentionally left blank ...
Page 110: ...This page is intentionally left blank ...
Page 786: ...This page is intentionally left blank ...
Page 812: ...This page is intentionally left blank ...
Page 836: ...This page is intentionally left blank ...
Page 838: ...This page is intentionally left blank ...
Page 845: ......