Note
Action
xx1300000543
Refit the arm house metal clamp.
2
Arrange the cables between the cable
clamps in the upper arm.
3
xx1300000668
Tip
Use tape and tie the axis-5 and axis-6
connectors and carrier into a bundle (if not
already done). This is done to facilitate the
procedure and to avoid damaging the parts
during the procedure.
This will also make it easier to run the cable
harness through the inside of the robot.
4
A
B
C
D
xx1400000382
A Gasket
B Cable guide
C Washer
D Cover
Foundry Plus
:
Make sure that the gasket underneath the
cover is correctly fitted. Replace if dam-
aged.
The gasket is covered with adhesive on the
side facing the upper arm cover. The three
washers are pressed into the holes in the
gasket. Make sure all three washers are
fitted.
5
Continues on next page
324
Product manual - IRB 6700
3HAC044266-001 Revision: N
© Copyright 2013 - 2018 ABB. All rights reserved.
4 Repair
4.5.1 Replacing the upper arm
Continued