1.3.9 Safety risks related to pneumatic/hydraulic systems
General
Special safety regulations apply to pneumatic and hydraulic systems.
Note
All components that remain pressurized after separating the machine from the
power supply must be provided with clearly visible drain facilities and a warning
sign that indicates the need for pressure relief before adjustments or performing
any maintenance on the robot system.
Residual energy
Residual energy can be present in these systems. After shutdown, particular care
must be taken.
The pressure must be released in the complete pneumatic or hydraulic systems
before starting to repair them.
Work on hydraulic equipment may only be performed by persons with special
knowledge and experience of hydraulics.
All pipes, hoses, and connections have to be inspected regularly for leaks and
damage. Damage must be repaired immediately.
Splashed oil may cause injury or fire.
Safe design
Gravity may cause any parts or objects held by these systems to drop.
Dump valves should be used in case of emergency.
Shot bolts should be used to prevent tools, etc., from falling due to gravity.
Product manual - IRB 6700
33
3HAC044266-001 Revision: N
© Copyright 2013 - 2018 ABB. All rights reserved.
1 Safety
1.3.9 Safety risks related to pneumatic/hydraulic systems
Summary of Contents for IRB 6700 Series
Page 1: ...ROBOTICS Product manual IRB 6700 ...
Page 46: ...This page is intentionally left blank ...
Page 110: ...This page is intentionally left blank ...
Page 786: ...This page is intentionally left blank ...
Page 812: ...This page is intentionally left blank ...
Page 836: ...This page is intentionally left blank ...
Page 838: ...This page is intentionally left blank ...
Page 845: ......