Refitting the wrist cover
Note
Action
A
B
xx1400000383
A Protection plugs (2 on wrist cover
and 2 on cover axis-5 gearbox)
B Washers (10 pcs) in gasket holes
Inspect the gasket. Replace if damaged.
Foundry Plus and Foundr Prime
:
•
Make sure that the gasket is undam-
aged on the cover. Replace if dam-
aged.
•
Put washers in the holes of the gas-
ket.
•
Use attachment screws made of
stainless steel to fit the wrist cover.
1
Tightening torque: 10 Nm.
xx1300000772
Refit the wrist cover. In order not to dam-
age the cable harness when the wrist cover
is refitted, use this method:
1
Hold the cover angled. See figure!
2
Catch any part of the cable harness
hanging down.
3
Lift the cover, still held in an angle.
4
Move the upper part of the cover into
position.
5
Secure the cover with its attachment
screws.
2
Remove the lifting accessories.
3
Concluding procedure
Note
Action
Pendulum Calibration is described in
Oper-
ating manual - Calibration Pendulum
, en-
closed with the calibration tools.
Re-calibrate the robot.
1
Axis Calibration is described in
with Axis Calibration method on page 798
General calibration information is included
in section
.
Continues on next page
338
Product manual - IRB 6700
3HAC044266-001 Revision: N
© Copyright 2013 - 2018 ABB. All rights reserved.
4 Repair
4.5.1 Replacing the upper arm
Continued
Summary of Contents for IRB 6700 Series
Page 1: ...ROBOTICS Product manual IRB 6700 ...
Page 46: ...This page is intentionally left blank ...
Page 110: ...This page is intentionally left blank ...
Page 786: ...This page is intentionally left blank ...
Page 812: ...This page is intentionally left blank ...
Page 836: ...This page is intentionally left blank ...
Page 838: ...This page is intentionally left blank ...
Page 845: ......