Note
Action
xx1400000372
Foundry Plus
:
Apply Mercasol in the hole for the locking
screw.
4
Jog axis-2 to:
•
-30° or +30°.
5
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot
working area.
6
Remove the Distance tool.
7
Screws: M10 quality 12.9.
Apply flange sealant and refit the cover
plate on the back of the balancing device.
8
Tightening torque: 50 Nm.
Flange sealant for conical fittings: Loctite
577.