Required tools and equipment
Note
Article number
Equipment, etc.
Lifting instruction 3HAC15880-2 en-
closed.
3HAC15556-1
Lifting accessory (chain)
Lifting instruction 3HAC15640-2 en-
closed.
3HAC15534-1
Lifting accessory, motor
Length: 1 m, lifting capacity: 1,000 kg.
-
Roundsling, 1 m
Used to push out the motor, if neces-
sary.
Always use removal tools in pairs.
Size depending on motor type, see
Type A vs type B motors on page 819
3HAC057339-003
3HAC057339-004
Removal tool
Always use guide pins in pairs.
3HAC15521-2
Guide pin, M10x150
300 mm, bits 1/2"
3HAC12342-1
Bits extender
Used to rotate the motor pinion.
3HAB7887-1
Rotation tool
Used to release the motor brakes.
-
24 VDC power supply
-
Leak-down tester
Required if Calibration Pendulum is the
valid calibration method for the robot.
3HAC15716-1
Calibration Pendulum toolkit
Delivered as a set of calibration tools.
Required if Axis Calibration is the valid
calibration method for the robot.
3HAC055412-001
Calibration tool box, Axis
Calibration
Content is defined in section
.
-
Standard toolkit
Deciding calibration routine
Decide which calibration routine to be used, based on the information in the table.
Depending on which routine is chosen, action might be required prior to beginning
the repair work of the robot, see the table.
Note
Action
Decide which calibration routine to use for
calibrating the robot.
•
Reference calibration. External cable
packages (DressPack) and tools can
stay fitted on the robot.
•
Fine calibration. All external cable
packages (DressPack) and tools
must be removed from the robot.
1
Follow the instructions given in the refer-
ence calibration routine on the FlexPendant
to create reference values.
If the robot is to be calibrated with refer-
ence calibration:
Find previous reference values for the axis
or create new reference values. These val-
ues are to be used after the repair proced-
ure is completed, for calibration of the ro-
bot.
Creating new values requires possibility to
move the robot.
Read more about reference calibration for
Axis Calibration in
.
If no previous reference values exist, and
no new reference values can be created,
then reference calibration is not possible.
Read more about reference calibration for
Pendulum Calibration in
Operating manu-
al - Calibration Pendulum
.
Continues on next page
Product manual - IRB 6700
531
3HAC044266-001 Revision: N
© Copyright 2013 - 2018 ABB. All rights reserved.
4 Repair
4.7.3 Replacing the axis-3 motor
Continued
Summary of Contents for IRB 6700 Series
Page 1: ...ROBOTICS Product manual IRB 6700 ...
Page 46: ...This page is intentionally left blank ...
Page 110: ...This page is intentionally left blank ...
Page 786: ...This page is intentionally left blank ...
Page 812: ...This page is intentionally left blank ...
Page 836: ...This page is intentionally left blank ...
Page 838: ...This page is intentionally left blank ...
Page 845: ......