Note
Action
There are two versions of the heat protec-
tion plates.
Remove the heat protection plate/plates
from the motor with the cabling still at-
tached to the plate.
5
Choose figure depending on which plate
is installed on the robot.
xx1500001030
Remove the heat protection plates from the
motor with the cabling still attached to the
plate.
xx1300000490
Continues on next page
558
Product manual - IRB 6700
3HAC044266-001 Revision: N
© Copyright 2013 - 2018 ABB. All rights reserved.
4 Repair
4.7.5 Replacing the axis-5 motor
Continued