Note
Action
Tightening torque: 10 Nm
xx1300000772
Refit the wrist cover. In order not to dam-
age the cable harness when the wrist cover
is refitted, use this method:
1
Hold the cover slightly tilted below
the wrist.
2
Put the cable harness inside the
cover.
3
Lift the cover, still tilted.
4
Move the upper part of the cover into
position.
5
Secure the cover with its attachment
screws.
3
Foundry Plus:
4
Refit protection plugs.
If used, refit the DressPack cable package
on the wrist.
5
Pendulum Calibration is described in
Oper-
ating manual - Calibration Pendulum
, en-
closed with the calibration tools.
Re-calibrate the robot.
6
Axis Calibration is described in
with Axis Calibration method on page 798
General calibration information is included
in section
.
DANGER
Make sure all safety requirements are met
when performing the first test run. These
are further detailed in the section
run may cause injury or damage on
page 26
.
7
570
Product manual - IRB 6700
3HAC044266-001 Revision: N
© Copyright 2013 - 2018 ABB. All rights reserved.
4 Repair
4.7.5 Replacing the axis-5 motor
Continued