6.3 Decommissioning of balancing device
General
There is much energy stored in the balancing device. Therefore a special procedure
is required to disassemble it. The coil springs inside the balancing device exert a
potentially lethal force unless disassembled properly.
The device must be disassembled by a decommissioning company.
Required equipment
Note
Article num-
ber
Equipment
Content is defined in section
-
Standard toolkit
Must protect against spatter of sparks
and flames.
-
Protective clothing that also covers
face and hands
For opening housing and cutting coils.
The long shaft is a safety requirement.
-
Cutting torch with a long shaft
These procedures include references
to the tools required.
Other tools and procedures may be
required. See references to these
procedures in the step-by-step in-
structions below.
DANGER
Do not,
under any circumstances, deal with the balancing device in any other
way than that detailed in the product documentation! For example, attempting
to open the balancing device is potentially lethal!
Action on field, decommissioning
The procedure below details the actions to perform on field, when the balancing
device is to be decommissioned.
Note
Action
Detailed in section
.
Remove the balancing device from the robot.
1
Make sure the decommissioning com-
pany is well informed about the stored
energy built up by high tensioned com-
pression springs and that the device
contains some grease.
Send the device to a decommissioning
company.
2
The following procedure contains useful
information about decommissioning.
Continues on next page
816
Product manual - IRB 6700
3HAC044266-001 Revision: N
© Copyright 2013 - 2018 ABB. All rights reserved.
6 Decommissioning
6.3 Decommissioning of balancing device
Summary of Contents for IRB 6700 Series
Page 1: ...ROBOTICS Product manual IRB 6700 ...
Page 46: ...This page is intentionally left blank ...
Page 110: ...This page is intentionally left blank ...
Page 786: ...This page is intentionally left blank ...
Page 812: ...This page is intentionally left blank ...
Page 836: ...This page is intentionally left blank ...
Page 838: ...This page is intentionally left blank ...
Page 845: ......