Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the safeguarded space.
2
Article number is specified in
quired tools and equipment on
page 140
.
If the lamp is not lit, trace the fault by:
•
inspecting whether the signal lamp is broken.
If so, replace it.
•
inspecting cable connections.
•
measuring the voltage in the connectors of
motor axis 3 (=24V).
•
inspecting the cabling. Replace the cabling if
a fault is detected.
3
Product manual - IRB 6700Inv
141
3HAC058254-001 Revision: L
© Copyright 2017 - 2020 ABB. All rights reserved.
3 Maintenance
3.3.16 Inspecting the signal lamp (option)
Continued
Summary of Contents for IRB 6700Inv
Page 1: ...ROBOTICS Product manual IRB 6700Inv ...
Page 16: ...This page is intentionally left blank ...
Page 40: ...This page is intentionally left blank ...
Page 182: ...This page is intentionally left blank ...
Page 672: ...This page is intentionally left blank ...
Page 704: ...This page is intentionally left blank ...
Page 720: ...This page is intentionally left blank ...
Page 722: ...This page is intentionally left blank ...
Page 729: ......