Note
Action
xx1600002046
Inspect the oil level at the vent hole (level
plug).
7
Required oil level is: 0 - 20 mm below the
oil plug hole.
More information is found in
oil level in axis-3 gearbox on page 108
.
Remove the oil dispenser.
8
Refit the protective cap on the nipple.
Tightening torque: 24 Nm
Refit the level plug.
9
DANGER
Make sure all safety requirements are met
when performing the first test run.
10
Product manual - IRB 6700Inv
161
3HAC058254-001 Revision: L
© Copyright 2017 - 2020 ABB. All rights reserved.
3 Maintenance
3.4.4 Changing oil, axis-3 gearbox
Continued