Disconnecting the axis-6 motor cables
Note
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
xx1200001080
Unscrew the attachment screws and re-
move the motor cover.
2
xx1300000488
Disconnect the motor cables.
3
xx1300000484
Unscrew the attachment screws that hold
the cable bracket.
4
Continues on next page
216
Product manual - IRB 6700Inv
3HAC058254-001 Revision: L
© Copyright 2017 - 2020 ABB. All rights reserved.
4 Repair
4.4.1 Removing the cable harness
Continued