Note
Action
xx1200001067
Remove the cable gland cover.
Make sure the gasket is not damaged.
Tip
Make a note in which direction the cable
gland hole is facing, if the motor will be re-
moved too. The motor shall be refitted in
the same position.
5
Use caution and pull out the motor cables.
6
Disconnecting the axis-5 motor cables
Note
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
xx1200001135
Unscrew the attachment screws and
washers and remove the motor cover.
2
Continues on next page