Note
Action
1150
xx1800000163
The bracket on the delivered fan cable must be
fitted at a distance of 1,150 mm from the base
connector.
If adjustment is needed: measure the distance
and make a mark with a pen or a piece of self
adhesive. Loosen the cable bracket nuts and
move the bracket to the mark. Tighten the nuts
with 10 Nm after adjustment.
3
xx1300000542
Loosen the frame cable clamp by unscrewing the
screws.
4
Cable straps
xx1800000164
Run the cabling up through the base and frame.
Make a loop of the fan cable and use cable straps
to strap it to the other cables.
5
xx1800000166
Secure the cable bracket inside the frame with
the two enclosed nuts.
6