3.4.5 Replacing the SMB battery
Note
The battery low alert (38213
Battery charge low
) is displayed when the battery
needs to be replaced. The recommendation to avoid an unsynchronized robot
is to keep the power to the controller turned on until the battery is to be replaced.
For a SMB board with 3-pole battery contact (RMU101 3HAC044168-001 or
RMU102 3HAC043904-001), the lifetime of a new battery is typically 36 months.
For a SMB board with 2-pole battery contact (DSQC), the typical lifetime of a new
battery is 36 months if the robot is powered off 2 days/week or 18 months if the
robot is powered off 16 h/day. The lifetime can be extended for longer production
breaks with a battery shutdown service routine. See
Operating manual - IRC5
with FlexPendant
for instructions.
WARNING
See instructions for batteries,
Safety risks during handling of batteries on page 35
.
Location of SMB battery
The SMB battery (SMB = serial measurement board) is located on the left hand
side of the frame as shown in the figure.
Battery pack with a 2-pole battery contact (DSQC)
xx0500002486
SMB battery cover
A
SMB battery pack
B
Battery cable
C
Continues on next page
Product manual - IRB 760
135
3HAC039838-001 Revision: M
© Copyright 2011-2018 ABB. All rights reserved.
3 Maintenance
3.4.5 Replacing the SMB battery
Summary of Contents for IRB 760 Series
Page 1: ...ROBOTICS Product manual IRB 760 ...
Page 8: ...This page is intentionally left blank ...
Page 46: ...This page is intentionally left blank ...
Page 96: ...This page is intentionally left blank ...
Page 144: ...This page is intentionally left blank ...
Page 394: ...This page is intentionally left blank ...
Page 400: ......
Page 401: ......