Note
Art.no.
Equipment, etc
These procedures include
references to the tools re-
quired.
Other tools and procedures may
be required. See references to
these procedures in the step-by-
step instructions below.
See chapter
.
Circuit diagram
Removing cable harness, upper end (incl. axis 6)
Use this procedure to remove the cable harness, upper arm (incl. axis 6).
Note
Action
This is done in order to facilitate updating
of the revolution counter.
Move the robot to the calibration position.
1
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot
working area.
2
Detailed in section
ness, lower end (axes 1-3) on page 153
If the complete cable harness is being re-
placed, start removal by removing the
cable
harness, lower end
.
3
xx1000001106
Remove the axis 6 motor cover by removing
its attachment screws, in order to reach the
connectors.
4
Continues on next page
Product manual - IRB 760
165
3HAC039838-001 Revision: M
© Copyright 2011-2018 ABB. All rights reserved.
4 Repair
4.3.2 Replacing the cable harness, upper end (incl. axis 6)
Continued