Note
Action
xx1000001417
Refit the
block for calibration
and the
axis 1
calibration plate
.
16
See
Performing a leak-down test on
.
Perform a leak-down test of the axis 1 gear-
box.
17
See
Changing oil, axis-1 gearbox on
.
Refill the axis 1 gearbox with lubricating oil.
18
Pendulum Calibration is described in
Operating manual - Calibration Pendulum
,
enclosed with the calibration tools.
Recalibrate the robot.
19
Axis Calibration is described in
ing with Axis Calibration method on
page 360
.
General calibration information is included
in section
DANGER
Make sure all safety requirements are met
when performing the first test run. These are
further detailed in the section
may cause injury or damage on page 26
20
Product manual - IRB 760
185
3HAC039838-001 Revision: M
© Copyright 2011-2018 ABB. All rights reserved.
4 Repair
4.3.5 Replacing the base, including axis 1 gearbox
Continued