Note
Art.no.
Equipment, etc.
F21 28x22, 4x12x9
3HAC4836-2
Protection plug
Content is defined in section
.
-
Standard toolkit
These procedures include refer-
ences to the tools required.
Other tools and procedures
may be required. See refer-
ences to these procedures
in the step-by-step instruc-
tions below.
Removing, parallel rod
Use this procedure to remove the parallel rod. The procedure is the same in both
ends of the parallel rod.
Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot
working area.
1
xx1100000088
CAUTION
Secure the upper arm with a roundsling in
an overhead crane or similar, in order to
avoid accidents.
2
Foundry Plus:
3
Remove the protection plugs
Continues on next page
254
Product manual - IRB 760
3HAC039838-001 Revision: M
© Copyright 2011-2018 ABB. All rights reserved.
4 Repair
4.4.7 Replacing the parallel rod
Continued