Note
Art.no.
Equipment, etc.
2 pcs, M12 x 50
Screw
For neutralizing the spring force of the
balancing cylinder.
3HAC039296-002
Lubrication tool
-
Lifting accessories
Permatex no. 3.
12360012-202
Sealing compound
Loctite 243
3HAB7116-1
Locking liquid
Content is defined in section
-
Standard toolkit
-
Ball bearing puller
Removing, balancing device
Use this procedure to remove the balancing device.
Note
Action
The balancing device must be placed
in a 90° angle from the floor, in order
the be lifted in the most secure way.
Move the robot to a position close enough to
its calibration position, to allow the lock screw
to be inserted into the hole for the lock screw.
1
See the figure in
xx1000001101
Lock the lower arm by inserting the
lock screw
into the
hole
.
CAUTION
Tighten by hand!
2
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot working
area.
3
Continues on next page